Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 638
Filtrar
1.
J Nanobiotechnology ; 18(1): 112, 2020 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-32778119

RESUMO

A method with high sensitivity, good accuracy and fast response is of ever increasing importance for the simultaneous detection of AA, DA and UA. In this paper, a simple and sensitive electrochemical sensor, which based on the polyvinylpyrrolidone (PVP)-graphene composite film modified glassy carbon electrode (PVP-GR/GCE), was presented for detecting ascorbic acid (AA), dopamine (DA) and uric acid (UA) simultaneously. The PVP-GR/GCE has excellent electrocatalytic activity for the oxidation of AA, DA and UA. The second-order derivative linear sweep voltammetry was used for the electrochemical measurements. The peak potential differences of DA-AA, DA-UA, and UA-AA (measured on the PVP-GR/GCE) were 212, 130 and 342 mV respectively. Besides, the over potential of AA, DA and UA reduced obviously, so did the peak current increase. Under the optimum conditions, the linear ranges of AA, DA and UA were 4.0 µM-1.0 mM, 0.02-100 µM, and 0.04-100 µM, respectively. The detection limits were 0.8 µM, 0.002 µM and 0.02 µM for AA, DA, and UA. The electrochemical sensor presented the advantages of high sensitivity and selectivity, excellent reproducibility and long-term stability. Furthermore, the sensor was successfully applied to the analysis of real samples.


Assuntos
Ácido Ascórbico/urina , Dopamina/urina , Técnicas Eletroquímicas/métodos , Ácido Úrico/urina , Grafite/química , Humanos , Limite de Detecção , Modelos Lineares , Povidona/química , Reprodutibilidade dos Testes
2.
Sensors (Basel) ; 20(5)2020 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-32106578

RESUMO

In this study, an efficient and simple designed nanohybrid created for individual and simultaneous detection of ascorbic acid (AA), dopamine (DA) and uric acid (UA). This nanohybrid is a combination of reduced graphene oxide (CRGO) and redox poly(para-phenylene) (Fc-ac-PP) modified in a lateral position with ferrrocenyl group CRGO/Fc-ac-PPP. The CRGO/Fc-ac-PPP nanohybrid demonstrated a synergistic effect resulting in a large conductivity, surface area and catalytic properties provided by the redox attached ferrocene. Moreover, this nanocomposite is able to detect individually as well as simultaneously AA, DA and UA in a co-existence system with defined and separated redox peaks oxidation. The linear response ranges for AA, DA and UA, when detected simultaneously, are 0.1-10000 µM, 0.0001-1000 µM and 0.1-10000 µM, respectively, and the detection limits (S/N = 3) are 0.046 µM, 0.2 nM and 0.013 µM, respectively. The proposed sensor shown satisfactory results when applied to real spiked urine samples for measuring the abnormal high or lowconcentration of AA, DA and UA in vivo.


Assuntos
Ácido Ascórbico/análise , Cicloparafinas/química , Dopamina/análise , Grafite/química , Compostos Macrocíclicos/química , Nanocompostos/química , Ácido Úrico/análise , Ácido Ascórbico/urina , Técnicas Biossensoriais , Dopamina/urina , Técnicas Eletroquímicas , Eletrodos , Compostos Ferrosos , Humanos , Metalocenos , Oxirredução , Reprodutibilidade dos Testes , Ácido Úrico/urina
3.
Sci Rep ; 10(1): 1487, 2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-32001750

RESUMO

Obesity is one of the major risk factor for cardiovascular and metabolic diseases. A disproportional accumulation of fat at visceral (VAT) compared to subcutaneous sites (SAT) has been suspected as a key detrimental event. We used non-targeted metabolomics profiling to reveal metabolic pathways associated with higher VAT or SAT amount among subjects free of metabolic diseases to identify possible contributing metabolic pathways. The study population comprised 491 subjects [mean (standard deviation): age 44.6 yrs (13.0), body mass index 25.4 kg/m² (3.6), 60.1% females] without diabetes, hypertension, dyslipidemia, the metabolic syndrome or impaired renal function. We associated MRI-derived fat amounts with mass spectrometry-derived metabolites in plasma and urine using linear regression models adjusting for major confounders. We tested for sex-specific effects using interactions terms and performed sensitivity analyses for the influence of insulin resistance on the results. VAT and SAT were significantly associated with 155 (101 urine) and 49 (29 urine) metabolites, respectively, of which 45 (27 urine) were common to both. Major metabolic pathways were branched-chain amino acid metabolism (partially independent of insulin resistance), surrogate markers of oxidative stress and gut microbial diversity, and cortisol metabolism. We observed a novel positive association between VAT and plasma levels of the potential pharmacological agent piperine. Sex-specific effects were only a few, e.g. the female-specific association between VAT and O-methylascorbate. In brief, higher VAT was associated with an unfavorable metabolite profile in a sample of healthy, mostly non-obese individuals from the general population and only few sex-specific associations became apparent.


Assuntos
Tecido Adiposo/metabolismo , Tecido Adiposo/patologia , Redes e Vias Metabólicas , Tecido Adiposo/diagnóstico por imagem , Adulto , Alcaloides/sangue , Ácido Ascórbico/análogos & derivados , Ácido Ascórbico/urina , Benzodioxóis/sangue , Biomarcadores/sangue , Biomarcadores/urina , Estudos Transversais , Feminino , Humanos , Hidrocortisona/sangue , Hidrocortisona/urina , Resistência à Insulina , Gordura Intra-Abdominal/diagnóstico por imagem , Gordura Intra-Abdominal/metabolismo , Gordura Intra-Abdominal/patologia , Imageamento por Ressonância Magnética , Masculino , Metaboloma , Pessoa de Meia-Idade , Tamanho do Órgão , Piperidinas/sangue , Alcamidas Poli-Insaturadas/sangue , Fatores Sexuais , Gordura Subcutânea/diagnóstico por imagem , Gordura Subcutânea/metabolismo , Gordura Subcutânea/patologia
4.
Ther Drug Monit ; 42(1): 139-145, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31318841

RESUMO

BACKGROUND: Gamma-hydroxybutyric acid (GHB) is a recreational drug with central nervous system depressing effects that is often abused. A urine GHB point-of-care test can be of great diagnostic value. The objective of this prospective study was to determine the performance of the new DrugCheck GHB Single Test and the Viva-E GHB immunoassay for urine samples in emergency department patients. METHODS: Patients presented to the emergency department of the OLVG hospital in Amsterdam with a Glasgow Coma Scale score <15 and potential drug of abuse intoxication were included in the study. Between June 2016 and October 2017, 375 patients were included. Using the DrugCheck GHB Single Test (Express Diagnostics Int'l, Blue Earth, MN) and the Viva-E GHB immunoassay (Siemens Healthineers, The Hague, the Netherlands), patients' urine samples were tested for GHB (cutoff for a positive result, 10 or 50 mcg/mL GHB). To ensure quality, the results obtained were compared with those generated using a validated gas chromatography method. The tests were considered reliable if specificity and sensitivity were both >90%. Possible cross-reactivity with ethanol was investigated by analyzing ethanol concentrations in patients' samples. RESULTS: Seventy percentage of the included patients was men, and the median age was 34 years old. The DrugCheck GHB Single Test's specificity and sensitivity were 90.0% and 72.9%, respectively, and using 50 mcg/mL as a cutoff value, its specificity and sensitivity improved to 96.7% and 75.0%, respectively. Serum and urine ethanol levels in the false-positive group were significantly higher compared with those in the true-negative group. The specificity and sensitivity of the Viva-E GHB immunoassay (cutoff value of 50 mcg/mL and excluding samples with ethanol levels ≥2.0 g/L) were 99.4% and 93.5%, respectively. CONCLUSIONS: The DrugCheck GHB Single Test's specificity was sufficient, whereas its sensitivity was poor, making it unsuitable for use at point-of-care. Contrarily, using 50 mcg/mL as the cutoff value and excluding samples with ethanol levels ≥2.0 g/L, the Viva-E GHB immunoassay showed acceptable results to detect clinically relevant GHB intoxications.


Assuntos
Hidroxibutiratos/urina , Imunoensaio/métodos , Adulto , Ácido Ascórbico/química , Ácido Ascórbico/urina , Cromatografia Gasosa , Etanol/química , Etanol/urina , Reações Falso-Positivas , Feminino , Humanos , Hidroxibutiratos/química , Masculino , Sensibilidade e Especificidade
6.
J Am Coll Nutr ; 39(5): 422-431, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31747355

RESUMO

Background: The efficacy of Vitamin C (L-ascorbic acid) supplementation can be assessed by uptake into the blood and retention in leukocytes. Vitafusion® Power C gummy is an alternative vitamin C source which may exhibit similar bioavailability to comparator caplets.Objective: The objective of this study was to evaluate the bioequivalence of vitamin C from a vitafusion® Power C gummy formulation and a comparator caplet in healthy adults.Methods: Thirty healthy men and women, 34.0 ± 11.4 years of age and Body Mass Index (BMI) 24.5 ± 3.6 kg/m2 completed the randomized examiner-blind, comparator controlled, cross-over trial with two sequences: gummy (1000 mg) to caplet (1000 mg) or caplet to gummy. Intake of foods fortified with Vitamin C was restricted 7 days prior to each dosing. Blood samples were collected pre-dose and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12 and 24 h post-dose for plasma and leukocytes; and urine was collected pre-dose and between 0-2, 2-4, 4-8, 8-12 and 12-24 h post-dose for L-ascorbic acid analysis.Results: Vitafusion® Power C gummy and comparator caplet demonstrated similar plasma absorption profiles as there were no significant differences in plasma L-ascorbic acid total Area Under the Curve (AUC)0-24h, and Tmax between gummy and caplet. The caplet did elicit a significantly higher Cmax than the gummy (p < 0.05), however, the difference was numerically small. Leukocyte L-ascorbic acid total AUC0-24h and Cmax were not significantly different between gummy and caplet, however Tmax of the gummy group was significantly longer (p = 0.012). Urinary L-ascorbic acid levels were also not significantly different between gummy and caplet. There were no serious adverse events and safety parameters remained within normal clinical range for both products.Conclusion: Vitafusion® Power C gummy exhibited similar Vitamin C absorption and bioavailability to a comparator caplet in healthy adults and were considered bioequivalent.


Assuntos
Ácido Ascórbico/farmacocinética , Composição de Medicamentos/métodos , Vitaminas/farmacocinética , Absorção Fisiológica , Administração Oral , Adulto , Área Sob a Curva , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Disponibilidade Biológica , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Leucócitos/química , Masculino , Método Simples-Cego , Equivalência Terapêutica , Vitaminas/sangue , Vitaminas/urina
7.
Mikrochim Acta ; 186(7): 466, 2019 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-31236752

RESUMO

A method is described for the determination of ascorbic acid (AA) in complex biological fluids. It based on maganese(II)-doped zinc/germanium oxide nanoparticles (Mn@ZnGe NPs) with appealing time-resolved phosphorescence (TRP). TRP can provide a background-free reporter signal in analytical methods. The absorption of AA overlaps the excitation band of Mn@ZnGe NPs at 254 nm. This reduces the intensity of fluorescence via an inner filter effect (IFE) with increasing concentration of AA. Typical experimental conditions include an emission peak at 536 nm, a delay time of 50 µs and a counting time of 2 ms. This method can detect AA in a range of 5-500 µM with a 0.13 µM limit of detection. If AA is oxidized by the enzyme AA oxidase (AAOx), dehydroascorbic acid will be formed which doesn't absorb at 254 nm. Hence, the IFE cannot occur and fluorescence is not reduced. The strategy can be used to quantify AAOx in the activity range of 1-4 U·mL-1. By using a handheld UV lamp and a smart phone with a color-scanning feature, the feasibility for visual detection and real-time/onsite quantitative scanometric monitoring of AA and AAOx is demonstrated. Graphical abstract Schematic presentation of a fluorometric method for determination of ascorbic acid (AA) and ascorbic oxidase and a scanometric visual assay. It based on the use of maganese(II)-doped zinc/germanium oxide nanoparticles (Mn@ZnGe NPs) with appealing time-resolved phosphorescence (TRP) and the inner-filter effect (IFE) between AA and Mn@ZnGe NPs.


Assuntos
Ascorbato Oxidase/análise , Ácido Ascórbico/análise , Corantes Fluorescentes/química , Nanopartículas Metálicas/química , Animais , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Ensaios Enzimáticos/instrumentação , Ensaios Enzimáticos/métodos , Germânio/química , Limite de Detecção , Masculino , Manganês/química , Ratos , Smartphone , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Zinco/química
8.
Anal Biochem ; 580: 1-13, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31153872

RESUMO

The presence of ascorbate in human urine has been shown to be a useful dietary, fruit or vitamin C intake biomarker. More recently it has been discovered that ascorbate levels in urine can be used to facilitate the detection of precancerous colorectal polyps. While there are a number elaborate HPLC, MS or multi-step enzymatic "kit" methods to detect and quantify urinary ascorbate, these are time consuming and expensive. There are also a number of low-cost paper-based ascorbate detection dipsticks. However, the limits of detection and quantification accuracy for these dipsticks are not adequate for applications with human urine. To address these limitations, we have developed a fast, sensitive, single-step colorimetric assay that can be used to quantify ascorbate in urine and other biological fluids. The assay uses the tetrazolium salt, methylthiazolyldiphenyl-tetrazolium bromide (MTT), with the electron carrier phenazine methosulfate (PMS), in a chelated acidic phosphate-buffer to produce a vivid purple color in the presence of ascorbate. Confirmation of the performance of the assay and of its standard curve in human urine was also done using independent LC-MS/MS and NMR analyses. The lower limit of detection of the ascorbate dipstick assay described here was found to be 3.2 µM. The paper dipsticks are stable over a wide range of temperatures and can be stored for up to 150-days.


Assuntos
Ácido Ascórbico/urina , Colorimetria/métodos , Voluntários Saudáveis , Humanos , Metilfenazônio Metossulfato/química , Sais de Tetrazólio/química
9.
Int J Mol Sci ; 20(9)2019 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-31072023

RESUMO

Consumption of nitrate-rich beetroot juice (BRJ) by athletes induces a number of beneficial physiological health effects, which are linked to the formation of nitric oxide (NO) from nitrate. However, following a secondary pathway, NO may also lead to the formation of N-nitroso compounds (NOCs), which are known to be carcinogenic in 39 animal species. The extent of the formation of NOCs is modulated by various other dietary factors, such as vitamin C. The present study investigates the endogenous formation of NOCs after BRJ intake and the impact of vitamin C on urinary NOC excretion. In a randomized, controlled trial, 29 healthy recreationally active volunteers ingested BRJ with or without additional vitamin C supplements for one week. A significant increase of urinary apparent total N-nitroso Compounds (ATNC) was found after one dose (5 to 47 nmol/mmol: p < 0.0001) and a further increase was found after seven consecutive doses of BRJ (104 nmol/mmol: p < 0.0001). Vitamin C supplementation inhibited ATNC increase after one dose (16 compared to 72 nmol/mmol, p < 0.01), but not after seven daily doses. This is the first study that shows that BRJ supplementation leads to an increase in formation of potentially carcinogenic NOCs. In order to protect athlete's health, it is therefore important to be cautious with chronic use of BRJ to enhance sports performances.


Assuntos
Antioxidantes/administração & dosagem , Desempenho Atlético , Beta vulgaris/química , Nitratos/administração & dosagem , Adolescente , Adulto , Antioxidantes/química , Ácido Ascórbico/administração & dosagem , Ácido Ascórbico/urina , Suplementos Nutricionais , Feminino , Sucos de Frutas e Vegetais , Humanos , Masculino , Pessoa de Meia-Idade , Nitratos/química , Nitratos/urina , Nitritos/urina , Compostos Nitrosos/urina , Raízes de Plantas/química , Adulto Jovem
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 213: 228-234, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30695741

RESUMO

In this work, we reported an economical plant-based hydrothermal method for one-pot green synthesis of water-soluble carbon dots (Tea-CDs) by using waste tea extract as a carbon source. The synthesized Tea-CDs were characterized by UV-visible, fluorescence, FT-IR, TEM, XPS and XRD. The Tea-CDs were found to remove hydroxyl and superoxide anion radical in vitro. In addition, the Tea-CDs exhibited bright blue fluorescence under UV-light (λex = 365 nm), and the fluorescence could be effectively quenched by CrO42- and Fe3+ ions. Meanwhile, the fluorescence of Tea-CDs-CrO42- and Tea-CDs-Fe3+ systems could be again easily recovered by ascorbic acid (AA) and L-cysteine (L-Cys). As an on-off-on fluorescent nano-sensor of the Tea-CDs, the sensitive detection of CrO42-, Fe3+, AA and L-Cys were all performed, showing that the good linear relationships between fluorescence intensity of Tea-CDs and concentration of all testing samples. Finally, the sensors successfully detected CrO42-, Fe3+, AA and L-Cys in commercially available real samples with satisfactory recovery ranges. The prepared sensors offer distinct advantages including low cost, simple handling, good sensitivity and high selectivity.


Assuntos
Antioxidantes/análise , Ácido Ascórbico/análise , Carbono/química , Compostos de Cromo/análise , Cisteína/análise , Ferro/análise , Pontos Quânticos/química , Chá/química , Ácido Ascórbico/urina , Compostos de Cromo/urina , Cisteína/urina , Sequestradores de Radicais Livres/química , Radicais Livres/química , Concentração de Íons de Hidrogênio , Ferro/urina , Espectroscopia Fotoeletrônica , Pontos Quânticos/ultraestrutura , Cloreto de Sódio/química , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
11.
Nanoscale ; 10(37): 17834-17841, 2018 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-30221263

RESUMO

Photoacoustic imaging (PAI) has emerged as a promising clinical technology, thanks to its high-resolution in deep tissues. However, the lack of specificity towards analytes limits further application of the PA probe in molecular imaging. To this end, we herein report a PA and fluorescence (FL) dual-modal probe for the selective detection of ascorbic acid (AA). To realize this design, cobalt oxyhydroxide (CoOOH) was adopted as a multifunctional platform (PA contrast agent, FL quencher and specific oxidant to AA) and hybridized with red-emissive carbon dots (RCDs). In the presence of AA, CoOOH is reduced to Co2+ and meanwhile releases RCDs, resulting in the decrease of PA and recovery of FL signals. We demonstrated the AA detection capabilities of the probe in complicated biological fluids (human serum and urine), living cells, and dual-modal FL/PA imaging in vivo. This work revealed the PAI capacity of CoOOH for the first time, which may inspire researchers to design other CoOOH-based PA probes and further employ RCDs in biology and the clinic.


Assuntos
Ácido Ascórbico/análise , Corantes Fluorescentes , Imagem Molecular , Técnicas Fotoacústicas , Animais , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Carbono , Cobalto , Humanos , Células MCF-7 , Camundongos Nus , Óxidos , Pontos Quânticos
12.
Biosens Bioelectron ; 121: 96-103, 2018 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-30199714

RESUMO

A novel and highly selective electrochemical sensing platform (ZnCl2-CF/GCE) based on combination of kiwi skin and zinc chloride nanoparticles was developed for the simultaneous detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The constructed electrode shows a high surface area and micro-mesoporous structure. And the electrochemical behaviors of the electrode were further explored by cyclic voltammetry (CV), impedance analysis (EIS), and differential pulse voltammetry (DPV). Under the optimal conditions, the ZnCl2-CF provides a high sensitivity and selective signaling in the co-existence system of AA, DA, and UA with linear response ranges of 0.05-200 µM, 2-2000 µM, and 1-2500 µM, respectively. The detection limits (S/N = 3) were calculated to be 0.02 µM, 0.16 µM, and 0.11 µM, respectively. In addition, the method has been successfully applied to determine AA, DA, and UA in real samples, which provides potential applications in further sensing study.


Assuntos
Ácido Ascórbico/urina , Técnicas Biossensoriais/métodos , Dopamina/urina , Técnicas Eletroquímicas , Ácido Úrico/urina , Urinálise/métodos , Biomassa , Técnicas Biossensoriais/instrumentação , Carbono/química , Eletrodos , Humanos , Limite de Detecção , Urinálise/instrumentação
13.
Biosens Bioelectron ; 119: 55-62, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30098467

RESUMO

Ascorbic acid, dopamine, and uric acid are important electroactive biomolecules for health monitoring and they coexist in serum or urine. Their quantitative determination by electrochemistry could provide the accurate reference for diseases diagnosis and treatment. However, the traditional electrochemical workstations are too large for on-field inspection. Hence, the design of handheld electrochemical system for the detection of biomolecules is significant for point-of-care testing (POCT). In this paper, a smartphone-based integrated voltammetry system using modified electrode was developed for simultaneous detection of biomolecules. The system contained a disposable sensor, a coin-size detector, and a smartphone equipped with application program. Screen-printed electrodes were used as sensors for the detection, on which reduced graphene oxide and gold nanoparticles were electrochemically deposited by the system. The detector was used with voltammetric methods, in which excitation voltage was applied on the sensors and subsequent current responses were detected. The smartphone is the core component to communicate with the detector, calculate data, and plot voltammograms in real-time. Then, the system was applied to detect standard solutions of the biomolecules and their mixtures as examples. The results showed that the peak currents of each substance increased with higher concentration and the method allowed the discrimination of the different potentials of the studied species. Finally, the practical applications of the system were tested through detections of the biomolecules in artificial urine. The results exhibited that the system could be used to detect electrochemical activity of biomolecules with linear, high sensitivity, and specific responses in point-of-care testing.


Assuntos
Ácido Ascórbico , Técnicas Biossensoriais/métodos , Análise Química do Sangue/métodos , Dopamina , Smartphone , Ácido Úrico , Urinálise/métodos , Ácido Ascórbico/análise , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Técnicas Biossensoriais/instrumentação , Análise Química do Sangue/instrumentação , Dopamina/análise , Dopamina/sangue , Dopamina/urina , Técnicas Eletroquímicas , Eletrodos , Ouro/química , Grafite/química , Humanos , Nanopartículas Metálicas , Ácido Úrico/análise , Ácido Úrico/sangue , Ácido Úrico/urina , Urinálise/instrumentação
14.
Anal Chim Acta ; 1029: 15-23, 2018 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-29907285

RESUMO

In this work, the three-dimensional nitrogen-doped nanostructured carbons with hierarchical architectures (3D-NNCsHAs) with high density of defective sites, high surface area and pluralities of pore size distributions was prepared through the pyrolysis of sea-tangle (Laminaria japonica), an inexpensive, eco-friendly and abundant precursor. Benefitting from their structural uniqueness, a selective and sensitive ascorbic acid (AA) sensor based on 3D-NNCsHAs was developed. Compared to the glassy carbon electrode (GCE) and the carbon nanotubes modified GCE (CNTs/GCE), the 3D-NNCsHAs modified GCE (3D-NNCsHAs/GCE) presents higher performance towards the electrocatalysis and detection of AA, such as lower detection limit (1 µM), wider linear range (10-4410 µM) and lower electrooxidation peak potential (-0.02 V vs. Ag/AgCl). In addition, 3D-NNCsHAs/GCE also exhibits high anti-interference and anti-fouling abilities for AA detection. Particularly, the fabricated 3D-NNCsHAs/GCE is able to determine AA in real samples and the results acquired are satisfactory. Therefore, the 3D-NNCsHAs can be considered as a kind of novel electrode nanomaterial for the fabrication of selective and sensitive AA sensor for the extensive practical applications ranging from food analysis, to pharmaceutical industry and clinical test.


Assuntos
Ácido Ascórbico/análise , Biomassa , Carbono/química , Análise Custo-Benefício , Laminaria/química , Nanotecnologia/economia , Nitrogênio/química , Ácido Ascórbico/química , Ácido Ascórbico/urina , Técnicas de Química Sintética/economia , Eletroquímica , Eletrodos , Análise de Alimentos , Humanos , Oxirredução
15.
Talanta ; 183: 122-130, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29567154

RESUMO

Carbon dots (CDs) have gained great attention as multifunctional materials because of their interesting properties and general applicability. However, there are some reports for the preparation of highly luminescent green-emitting CDs (G-CDs), although these reports seem not to be extensible. Herein, new G-CDs (quantum yield: 27.2%) were synthesized from a facile hydrothermal treatment of p-aminosalicylic acid and ethylene glycol dimethacrylate as both carbon and nitrogen source and cross-linking agent, respectively. The chemical composition and optical properties of the as-prepared G-CDs were successfully investigated using transmission electron microscopy, atomic force microscopy, dynamic light scattering, X-ray diffraction, energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy and fluorescence and UV-vis spectroscopies. Interestingly, the fluorescence intensity of G-CDs was selectivity quenched by Fe3+ in the range of 0.05-10.0 µmol L-1, with a detection limit of 13.7 nmol L-1. Meanwhile, ascorbic acid found to reduce Fe3+ to Fe2+, thereby causing restoration of the fluorescence of G-CDs. The detection limit for ascorbic acid detection was estimated as 82.0 nmol L-1 over a linear range from 0.2 to 11.0 µmol L-1. Furthermore, the designed sensing platform was successfully utilized to the detection of Fe3+ and ascorbic acid in water and urine samples and to intracellular imaging without surface modification.


Assuntos
Ácido Ascórbico/análise , Carbono/química , Compostos Férricos/análise , Pontos Quânticos/química , Urinálise/métodos , Poluentes Químicos da Água/análise , Adulto , Ácido Ascórbico/urina , Carbono/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Compostos Férricos/urina , Fluorescência , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacologia , Voluntários Saudáveis , Humanos , Íons/análise , Estrutura Molecular , Imagem Óptica , Tamanho da Partícula , Rios/química , Células Tumorais Cultivadas , Adulto Jovem
16.
J Clin Lab Anal ; 32(5): e22390, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29479748

RESUMO

BACKGROUND: Study was performed in order: (i) to assess the comparability of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; (ii) to assess accuracy of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; and (iii) to evaluate interference of ascorbic acid on the glucose, bilirubin, hemoglobin, and nitrite determination using 2 different dipsticks: iChem Velocity, Iris Diagnostics and Combur-10M, Roche Diagnostics. METHODS: Random urine specimens were included in the study. Comparability, accuracy, and ascorbic acid interference testing were performed. RESULTS: Obtained results have shown almost perfect agreement for all parameters between 2 dipsticks in samples with negative ascorbic acid. Agreement in samples with positive ascorbic acid was not acceptable for bilirubin, protein, nitrite, and hemoglobin. Accuracy was not acceptable for hemoglobin and leukocyte esterase on both dipsticks. Ascorbic acid interference examination has shown that intensity of interference differs between dipsticks. Ascorbic acid interferes with glucose, hemoglobin, nitrite, and bilirubin at different concentrations causing false-negative results. CONCLUSION: Obtained results indicate that it is necessary to determine diagnostic accuracy of used dipstick in order to define purpose of urinalysis. It is very important to choose dipstick with ascorbic acid indicator and to examine ascorbic acid impact on dipstick analytes independently of manufacturer claims.


Assuntos
Ácido Ascórbico/urina , Urina/química , Bilirrubina/urina , Reações Falso-Negativas , Feminino , Glicosúria/metabolismo , Hemoglobinas/metabolismo , Humanos , Masculino , Urinálise
17.
Anal Chim Acta ; 1003: 49-55, 2018 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-29317029

RESUMO

In this work, we developed a sensitive and highly selective fluorescent approach for the detection of ascorbic acid (AA) by taking advantage of the oxidative etching effect of iodine (I2) on the lysozyme-stabilized silver nanoclusters (dLys-AgNCs) with fluorescence quenching. I2 could be produced from the redox reaction between iodate (IO3-) and AA, and thus the fluorescence intensity of dLys-AgNCs was turned off significantly in the coexistence of IO3- and AA. The fluorescence quenching of dLys-AgNCs had a good linear relationship with AA concentration, which allowed the detection of AA in the range from 0.05 to 45.0 µmol L-1 with a detection limit of 20 nmol L-1. The quenching mechanism was elucidated by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), zeta potential, and dynamic light scattering (DLS) measurements, confirming that the fluorescence quenching of the dLys-AgNCs was attributed to the oxidative etching of the in situ generated I2, inducing aggregation of the dLys-AgNCs probe by forming Ag@AgI nanocomposite. The dLys-AgNCs probe exhibited excellent selectivity for AA sensing over several common reducing agents tested. Moreover, this approach was extended to the detection of AA in orange juice and urine with recovery rates in the range of 96.0% (RSD: 4.11) to 100.9% (RSD: 3.28) and 94.5% (RSD: 6.40) to 99.2% (RSD: 5.36), respectively.


Assuntos
Ácido Ascórbico/análise , Técnicas de Química Analítica/instrumentação , Iodo/química , Muramidase/química , Nanoestruturas/química , Prata/química , Animais , Ácido Ascórbico/química , Ácido Ascórbico/urina , Sucos de Frutas e Vegetais/análise , Limite de Detecção , Modelos Moleculares , Conformação Molecular , Oxirredução , Espectrometria de Fluorescência
18.
J Immunoassay Immunochem ; 38(4): 430-437, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28422565

RESUMO

OBJECTIVES: Recent studies have highlighted the role of oxidative stress in the pathogenesis of lichen planus (LP). In the present study, the interest of the authors is focused on the investigation of ascorbic acid status in patients with LP and identification of parameters that might influence the level of this vitamin. MATERIAL AND METHOD: We analyzed the level of urinary ascorbic acid (reflectometric method) in 77 patients with LP (cutaneous LP (CLP)-49 cases; oral LP (OLP)-28 cases) and 50 control subjects. The evaluation of all participants included clinical examination and laboratory and imaging tests. RESULTS: Compared to the control group (19.82 mg/dl) the level of ascorbic acid was significantly lower both in patients with CLP (8.47 mg/dl, p = 0.001) and in those with OLP (8.04 mg/dl, p = 0.001). In patients with LP it was found that the deficiency of ascorbic acid increases with age (r = -0.318, p = 0.032). The urinary concentrations of ascorbic acid were significantly lower in patients with LP associated with infections compared to patients with LP without infections. CONCLUSIONS: The urinary ascorbic acid level may be a useful parameter in identifying patients with LP who are at risk of developing viral or bacterial infections.


Assuntos
Deficiência de Ácido Ascórbico/complicações , Deficiência de Ácido Ascórbico/diagnóstico , Ácido Ascórbico/urina , Líquen Plano/complicações , Líquen Plano/diagnóstico , Deficiência de Ácido Ascórbico/imunologia , Feminino , Humanos , Líquen Plano/imunologia , Masculino , Pessoa de Meia-Idade
19.
Talanta ; 162: 135-142, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27837809

RESUMO

Recently, carbon dots (CDs) have drawn extensive attention owing to their unique properties. While more and more research had been focusing on the exploration of CDs as fluorescence sensors, the blue or green fluorescence emission of CDs restricts further applications of CDs, particularly in the biology-relevant fields due to the commonly blue auto-fluorescence of biological matrix. Therefore, the preparation of CDs with strong emission at long wavelengths is highly desirable. For these situations, a facile, straightforward and extra-reductant needless method was established to fabricate silver-carbon dot nanohybrid with enhanced near-infrared fluorescence through metal-enhanced fluorescence (MEF). We applied the Ag-CD nanohybrid as a probe to detect antioxidants such as ascorbic acid in near-infrared window, and the probe possesses a linear range of 0.2-60µM. More importantly, this sensor could not only function in aqueous solution, but also display well selective response in intricate biological fluids. In addition, an IMPLICATION logic gate was constructed based on the unique characteristics of Ag-CD nanohybrid which presages more opportunities for application in single and multiple biological sensing.


Assuntos
Ácido Ascórbico/análise , Carbono/química , Nanoestruturas/química , Pontos Quânticos , Prata/química , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Humanos , Microscopia Eletrônica de Transmissão , Nanoestruturas/ultraestrutura , Reprodutibilidade dos Testes , Espectrofotometria/métodos , Difração de Raios X
20.
J Fluoresc ; 27(1): 293-302, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27796631

RESUMO

In this report, a novel one-step chemical reduction method was reported for synthesis of water-soluble and stable fluorescent glutathione-templated silver nanocluster (GSH-Ag NCs) with ascorbic acid as an environmental-friendly reducing agent. On the basis of an oxidoreduction-induced fluorescence quenching mechanism, the prepared GSH-Ag NCs found to act as a cheap, non-toxic and highly sensitive "turn-off" fluorophore for ascorbic acid (AA). Furthermore, the fluorescence of the fluorophore/AA system could be recovered through addition of arginine (Arg), which made the system function as a highly selective "turn-on" sensor for arginine. Therefore, a "turn-off-on" switch sensor was proposed for detection of AA and Arg. Under optimized conditions, the probe gives a fluorescent response that is linear in the 2-300 µM concentration range of AA, with a detection limit of 0.1 µM. The probe for Arg, in turn, has a linear range in the 10-180 µM concentration range, and the limit of detection is 0.5 µM. In addition, the developed method showed great accuracy when employed to detect AA and Arg in human urine and serum, which shows its great potential in biological molecular recognition applications.


Assuntos
Arginina/sangue , Arginina/urina , Ácido Ascórbico/sangue , Ácido Ascórbico/urina , Técnicas Biossensoriais/métodos , Corantes Fluorescentes/química , Nanopartículas Metálicas/química , Prata/química , Fluorescência , Glutationa/química , Humanos , Limite de Detecção , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...